Balcony Railing Spacing Standards Do Not Affect The Balcony Safety

General principles of the civil architecture design 6. 6. 3 balcony, and outside gallery, and indoor cloister, and within patio, and master roofing and the outdoor stairs, Pro space should set protection railing, and should meet following provides: 1 railing should to substantial, and durable of material making, and can bear load contains specification provides of level load contains; 2 Pro empty height in 24m following Shi, railing height not should below 1.05m, Pro empty height in 24m and the 24m above (including in the senior residential) Shi, railing height not should below 1.10m; Note: the railing height from floor to railing or roof top height calculation, if width is greater than or equal to 0.22m at the bottom, and a height of less than or equal to 0.45m step part of from the riding position counted from the top. 3 railing away from floor surface or roofing 0.10m height within should not be blank; 4 residential, and nursery, and kindergarten, and elementary and middle schools and the children dedicated activities places of railing must used prevent children climbing of structure, dang used vertical rod pieces do railing Shi, its rod pieces NET from not should is greater than 0.11M; 5 culture entertainment building, and commercial service building, and sports building, and garden landscape building, allows children into activities of places, dang used vertical rod pieces do railing Shi, its rod pieces NET from also not should is greater than 0.11M.